The Eaton 9155 is a Double-Conversion Online, Split-Phase UPS and requires a hardwired input connection of 200-240VAC with Neutral or with Optional Input Transformer Module. The optional input transformer module is used to provide a neutral connection for the UPS input when none exists in present building wiring. Output Voltage is 100/200, 110/220, 120/240 with 180° phase displacement or 120/208, 127/220 with 120° phase displacement.
General | |
Topology | Double-conversion |
Catalog Number | K40813000000000 |
Part Number | K40813000000000 |
Color | Black |
Rating (VA/Watts) | 8000/7200 |
Diagnostics | Full system self-test at startup |
UPS Bypass | Automatic on overload or UPS failure |
Dimensions (H x W x D, inches) | 47.8 x 12 x 33.7 |
Weight (lbs) | 558 |
Warranty | Two-year factory warranty |
Contents (Ships with the following items) | 1 ready-to-go UPS Software Suite CD User Guide |
Efficiency | 92% with nominal linear load; 91% with nominal computer load. |
Electrical Input | |
Connection | Hardwired - see manual for terminal block layout |
Frequency | 50/60 Hz (45 to 65 Hz) |
Frequency Range | 45 to 65 Hz |
Input Power Factor | P.F >0.99 typical, >0.96 frequency converter |
Generator Compatability | Yes |
Electrical Output | |
100/200, 110/220, 120/240 Vac 180° phase displacement; 120/208, 127/220 Vac 120° phase displacement | |
Output Receptacles | (1) PDM |
On Utility Voltage Regulation | Output voltage regulation ±1% Static; ±5% dynamic at 100% resistive load change |
On Battery Voltage Regulation | Output voltage regulation ±1% Static; ±5% dynamic at 100% resistive load change |
Overload Capacity | 150% for 5 sec / 125% for 1 min (online), 110% for 10 min |
Voltage Wave Shape (On Battery) | Sine Wave |
Transfer Time | 0 ms |
Battery | |
Battery Type | 9Ah, sealed, lead-acid, maintenance-free |
Battery Replacement | Field-replaceable |
Start On Battery | Allows start of UPS without utility input |
Recharge Time | Internal battery: approximately 3 hours to 80% usable capacity at nominal line voltage after full load discharge External battery: no more than 10x discharge time to 90% usable capacity at nominal line voltage after full load discharge |
Communications | |
User Interface | LCD Display with blue backlight |
LEDs | (4) LEDs for notice and alarm |
Audible Alarms | Yes |
Communication Ports | (1) RS-232, (1) relay contact, (1) REPO, (2) environmental input |
Communications Slot | (2) X-Slot communication bays |
Power Management Software | Bundled Software Suite CD |
Environmental & Standards | |
Audible Noise | <53dBA at 1 meter (noise less room) typical |
Operating Temperature | 10°C to +40°C, +45°C with 7.5% derating; Batteries recommended max. +25�C |
Markings | UL, cUL, CSA, CE and NOM-NYCE |
Storage Temperature | -15°C to +25°C |
Relative Humidity | 0-95%, non condensing |